D550 GC

Bore
5.7 in / 145 mm
Stroke
7.2 in / 183 mm
Displacement
1106 in³ / 18.1 l

The D550 GC diesel generator sets were developed to meet your needs in a standby application. Producing reliable power of 550 ekW at 60 Hz, meeting ISO 8528-5 transient response requirements and built to accept 100 % rated load in one step. Our D550 GC generator sets meet EPA Stationary Emergency (Tier 2) certified emissions requirements.

Generator Set Specifications
Maximum Rating 550 ekW
Minimum Rating 550 ekW
Emissions/Fuel Strategy EPA Stationary Emergency
Voltage 480 to 600 Volts
Frequency 60 Hz
Speed 1800 rpm
Duty Cycle Standby
Engine Specifications
Engine Model Cat® C18 In-line 6, 4-cycle diesel
Bore 5.7 in / 145 mm
Stroke 7.2 in / 183 mm
Displacement 1106 in³ / 18.1 l
Compression Ratio 14.5:1
Aspiration Turbocharged Air-to-Air Aftercooled
Fuel System MEUI
Governor Type ADEM™A4
Generator Set Dimensions
Length - Maximum 196.1 in / 4980 mm
Width - Maximum 73.4 in / 1865 mm
Height - Minimum 79.1 in / 2009 mm
Height - Maximum 100.9 in / 2563 mm
Dry Weight - Genset (minimum) 8776.6 lb / 3981 kg
Dry Weight - Genset (maximum) 11464 lb / 5200 kg

Standard Equipment

  • Air Inlet System
    • Air cleaner - Non canister, disposable
    • Aftercooler core
    • Turbocharger
  • Control Panel
    • GCCP 1.2
  • Cooling System
    • Jacket water pump, gear driven, centrifugal
    • Radiator, package mounted
    • Radiator sight gauge
    • Thermostats and housing
    • Blower fan and fan drive with guards
    • Coolant drain valve
  • Exhaust System
    • Exhaust manifold - dry
  • Fuel System
    • Fuel priming pump
    • Primary fuel filter w/integral water separator and secondary filter, spin on
    • Engine fuel transfer pump
    • Fuel cooler
    • Integral tank base, 24 hours, UL142
  • Generator Set
    • Complete system designed & built at ISO 9001:2000 certified facilities
    • All protective devices and control functions simulated and checked
    • Factory tested to design specifications at full load conditions
  • Generators and Generator Attachments
    • Insulation system, Class H
    • Standard winding protection for non-harsh environments with relative humidity ? 95%
    • Terminal box, IP22 RHS facing, bottom cable entry
    • IP23 Protection
    • 6 Leads
    • Voltage regulator (single phase sensing)
    • Easy access to AVR and terminals
    • Brushless, self-excited 2/3 pitch (600V uses Internal excitation (IE))
  • Governing System
    • Cat electronic governor (ADEM A4)
  • Lube System
    • Lubricating oil, CK-4 (10W-30)
    • Oil cooler
    • Oil drain with valve
    • Shallow oil pan
    • Oil filter, spin on
    • Fumes disposal to front of radiator
    • Oil filler and dipstick
  • Mounting System
    • Captive linear vibration isolators between base and engine-generator
    • Includes lifting provisions and termination points for coolant and lube oil drain lines
  • Protection
    • Safety shutoff - Overspeed
    • Safety shutoff - Low oil pressure
    • Safety shutoff - High water temperature
  • Starting/Charging System
    • 24-volt electric starting motor
    • 24V, 45 Amp Charging alternator
  • General
    • Lifting eyes
    • Parts book
    • Vibration damper

Optional Equipment

  • Air Inlet System
    • Air cleaner (Non canister disposable)
  • Bases, Mounting & Fuel Tanks
    • Integral tank base, 24 hours, UL142
    • Fuel tank pill pipe & lockable cap
    • Audio & visual fuel alarm (@90% fuel level)
    • 5 Gallon Spill Containment
    • Overfill prevention valve
    • Wide Base - Skid
  • Circuit breaker
    • 400A LS/I
    • 1200A LS/I
    • Auxiliary contacts
    • 800A LSI
    • 800A LS/I
    • 600A LSI
    • 600A LS/I
    • 400A LSI
    • 1200A LSI
  • Control System
    • Volt free contacts
    • 20A GFCI (Ground Fault Circuit Interrupter)
    • 16 -light NFPA 99/110 Annunciator
    • Twist release, Red button emergency stop
    • Product link remote monitoring hardware
    • 100A Load center
    • Ground fault relay
    • Audible alarm Gp
    • Annunciators box
    • Remote E-Stop button
    • Local annunciator
    • Discrete I/O module
    • Volt free contact
    • Earth (Ground) fault relay
  • Enclosures
    • Sound attenuated Level 2 enclosure (White)
    • AC & DC Source lights
    • E-Stop
    • Sound attenuated enclosure
  • Exhaust System
    • Flexible exhaust connection
    • Manifold and turbocharger guards
    • 8" Muffler - 25 dBA attenuation
  • Generator
    • Space heater
    • Permanent magnet excitation (PMG) generator
  • Starting System
    • Standard battery set: 1000 CCA, 90 amp/hr.
    • Battery charger (UL Certified)
    • Jacket water heater
    • Oversize battery set, 1400 CCA, 200 amp/hr
  • General
    • CSA Certification
    • Extended Service Coverage
    • UL2200 Certification
    • Generator test report
    • Tool set
  • Circuit breakers
    • Single LSI motorised circuit breaker
    • Auxiliary contacts
    • Neutral bar (208V)
  • Cooling System
    • Jacket water heater with pump
    • Coolant heater
    • Stone guards
  • Base / Fuel Tank
    • Audio & visual fuel alarm
  • Fuel System
    • Integral 8 hour tank base
  • Starting and Charging
    • Oversize battery set
    • Battery disconnect switch
    • 5 Amp Battery charger
    • Standard battery set
  • Certifications
    • UL2200 Listed
    • CSA 22.2
    • Seismic
  • Lube System
    • Manual sump pump
Contact Us
x

We're here to help

We'll do our best to get back to you as soon as possible.