DE150 GC (60 Hz)

Bore
4.1 in / 105 mm
Stroke
5.3 in / 135 mm
Displacement
427.8 in³ / 7 l

Producing reliable power of 132 ekW at 60 Hz, our DE150 GC diesel generator set is designed to meet ISO 8528-5 transient response requirements.

Generator Set Specifications
Maximum Rating 132 ekW
Minimum Rating 132 ekW
Emissions/Fuel Strategy Non Regulated
Voltage 220 to 480 Volts
Frequency 60 Hz
Speed 1800 rpm
Duty Cycle Standby
Engine Specifications
Engine Model C7.1 I-6, 4-Cycle Diesel
Bore 4.1 in / 105 mm
Stroke 5.3 in / 135 mm
Displacement 427.8 in³ / 7 l
Compression Ratio 18.2:1
Aspiration Turbocharged
Fuel System Inline
Governor Type Mechanical
Generator Set Dimensions
Length - Maximum 130.9 in / 3325 mm
Width - Maximum 44.6 in / 1134 mm
Height - Maximum 65.6 in / 1666 mm
Dry Weight - Genset (maximum) 4043 lb / 1834 kg

Standard Equipment

  • Engine
    • C7.1, Inline 6 cylinder, 4 stroke diesel
  • Control Panels
    • GCCP 1.1
  • Fuel Storage
    • Single wall 8 hour fuel tank
  • Governor
    • Mechanical governor
  • Enclosure
    • Cat GC enclosure
  • Alternator
    • A Frame standard alternator
  • Air, Cooling & Exhaust
    • Enclosure silencer
  • General
    • Engine and alternator pre-paint, Caterpillar yellow

Optional Equipment

  • Auxiliary Supply Voltage
    • 120V
  • Certification
    • Certificate of Conformance
    • Australia, CIS, Gulf Certification
  • Alternator Requirements
    • Space heater
  • Fuel Storage
    • Dual wall 8 hour fuel tank
    • Low fuel level alarm
    • High fuel level alarm
    • Low fuel level shutdown
    • Single wall tank with containment
  • Circuit breaker
    • 3 Pole Circuit breaker 630A
    • 4 Pole Circuit breaker 250A
    • 4 Pole Circuit breaker 200A
    • 3 Pole Circuit breaker 250A
    • 3 Pole Circuit breaker 200A
    • 4 Pole Circuit breaker 400A
    • 4 Pole Circuit breaker 630A
    • Circuit breaker padlock
    • Neutral earth link
    • Overload via alarm switch on breaker
    • 3 Pole Circuit breaker 400A
  • Genset Control
    • Panel mounted audible alarm
    • Battery charger
    • Earth leakage
    • Volt free contacts for genset running
    • Volt free contacts for common alarm
    • Earth fault
    • Emergency stop with key
    • USB to RS485 Communications device
    • Coolant heater
    • Battery
    • Low coolant level shutdown
    • Standby Pack (Smart Jacket water heater, Battery charger)
  • Testing & Packaging
    • PGS Test report @ 1.0 power factor
    • PGS Test report @ 0.8PF