DE88 GC (60 Hz)

Bore
4.1 in / 105 mm
Stroke
5 in / 127 mm
Displacement
268.5 in / 4.4 l

Producing reliable power of 80 ekW at 60 Hz, our DE88 GC diesel generator set is designed to meet ISO 8528-5 transient response requirements.

Generator Set Specifications
Maximum Rating 80 ekW
Minimum Rating 80 ekW
Emissions/Fuel Strategy Non Regulated
Voltage 220 to 480 Volts
Frequency 60 Hz
Speed 1800 rpm
Duty Cycle Standby
Engine Specifications
Engine Model C4.4, In-line 4, 4-cycle diesel
Bore 4.1 in / 105 mm
Stroke 5 in / 127 mm
Displacement 268.5 in / 4.4 l
Compression Ratio 17.25:1
Aspiration Turbocharged
Fuel System Inline
Governor Type Mechanical
Generator Set Dimensions
Length - Maximum 89.6 in / 2275 mm
Width - Maximum 43.3 in / 1099 mm
Height - Maximum 57.7 in / 1465 mm
Dry Weight - Genset (maximum) 1245 lb / 2745 kg

Standard Equipment

  • Engine
    • C4.4, Inline 4 cylinder, 4 stroke diesel
  • Governor
    • Mechanical governor
  • Alternator
    • A Frame standard alternator
  • Fuel Storage
    • Single wall 8 hour fuel tank
  • Genset Control
    • GCCP 1.1
  • Enclosure
    • Cat GC enclosure
  • Air, Cooling & Exhaust
    • Enclosure silencer
  • General
    • Engine and alternator pre-paint, Caterpillar yellow

Optional Equipment

  • Auxiliary Supply Voltage
    • 120V
  • Certification
    • Australia, CIS, Gulf Certification
    • Certificate of Conformance
  • Alternator Requirements
    • Space heater
  • Fuel Storage
    • Low fuel level shutdown
    • Single wall tank with containment
    • Dual wall 8 hour fuel tank
    • Low fuel level alarm
    • High fuel level alarm
  • Genset Control
    • Volt free contacts for genset running
    • Earth fault
    • Panel mounted audible alarm
    • USB to RS485 Communications device
    • Emergency stop with key
    • Earth leakage
    • Battery charger
    • Volt free contacts for common alarm
    • Coolant heater
    • Standby Pack (Smart Jacket water heater, Battery charger)
    • Battery
    • Low coolant level shutdown
  • Circuit breaker
    • 3 Pole Circuit breaker 160A
    • 3 Pole Circuit breaker 125A
    • 3 Pole Circuit breaker 200A
    • 3 Pole Circuit breaker 400A
    • 4 Pole Circuit breaker 160A
    • 4 Pole Circuit breaker 125A
    • 3 Pole Circuit breaker 250A
    • 4 Pole Circuit breaker 250A
    • 4 Pole Circuit breaker 200A
    • Circuit breaker padlock
    • 4 Pole Circuit breaker 400A
    • Neutral earth link
    • Overload via alarm switch on breaker
  • Testing & Packaging
    • PGS Test report @ 1.0 power factor
    • PGS Test report @ 0.8PF
Contact Us
x

We're here to help

We'll do our best to get back to you as soon as possible.